DOI:

Received February 19, 1998,Revised May 29, 1998, Accepted , Available online

Volume 11,1999,Pages 93-99

  • Summary
  • References
  • Related Articles
Based on the tests between anoxic and aerobic process, the two-stage aerobic process with a biological selector was chosen to treat terephthalic acid wastewater (PTA). By adopting the two- stage aerobic process, the CODCr in PTA wastewater could be reduced from 4000-6000 mg/L to below 100 mg/L; the COD loading in the first aerobic tank could reach 7.0-8.0 kgCODCr/(m3.d) and that of the second stage was from 0.2 to 0.4 kgCODCr/(m3.d). Further researches on the kinetics of substrate degradation were carried out.

Copyright © Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. and Science Press. All rights reserved.京ICP备05002858号-3